ballistics_engine/
profile.rs

1//! Saved ballistic profile data model.
2//!
3//! `ProfileData` is the schema of `~/.ballistics/profiles/<name>.json` — the CLI's saved
4//! profiles — and, since the bridge grew `profile.validate`/`profile.normalize`/
5//! `profile.import_a7p`, also the profile document the JSON command bridge exchanges with
6//! embedding apps. It lived in `main.rs` from its introduction; it moved here VERBATIM so
7//! the bridge and the CLI share one definition. The serde wire shape is a compatibility
8//! contract: every stored profile on disk and every fixture in the test suite must keep
9//! loading, so field names, defaults, `skip_serializing_if` decisions, and the ABSENCE of
10//! `deny_unknown_fields` (unknown keys are tolerated and dropped, the documented
11//! forward-compat behavior) are all deliberately unchanged. See the round-trip test at the
12//! bottom of this file before touching any attribute.
13//!
14//! fs-free by design: this module must compile for wasm32, so file persistence
15//! (`save_profile`/`load_profile`) and unit conversion of loaded profiles (`converted_to`,
16//! which rides on the CLI's `UnitConverter`) stay in `main.rs`.
17
18use serde::{Deserialize, Serialize};
19
20use crate::adjustment::parse_click_value;
21use crate::cli_api::UnitSystem;
22use crate::optic::{HoldBounds, OpticProfile, TravelLimits, TurretState};
23use crate::reticle::ReticleDescription;
24use crate::truing_dsf::DsfPoint;
25
26/// Saved ballistic profile for quick recall
27#[derive(Debug, Clone, Serialize, Deserialize)]
28pub struct ProfileData {
29    pub name: String,
30    pub velocity: f64,
31    pub bc: f64,
32    pub mass: f64,
33    pub diameter: f64,
34    pub drag_model: String,
35    #[serde(default)]
36    pub twist_rate: Option<f64>,
37    #[serde(default)]
38    pub sight_height: Option<f64>,
39    #[serde(default)]
40    pub zero_distance: Option<f64>,
41    #[serde(default = "default_unit_system")]
42    pub units: String,
43    #[serde(default = "default_temperature")]
44    pub temperature: f64,
45    #[serde(default = "default_pressure")]
46    pub pressure: f64,
47    /// True when the stored temperature was a supplied reading (0.49.0+). Absent/false = unknown:
48    /// files written before 0.49.0 cannot tell a typed 59 °F from the default, so they keep the
49    /// legacy rule (59 °F / 15 °C at a real altitude flies the ICAO standard temperature).
50    #[serde(default, skip_serializing_if = "std::ops::Not::not")]
51    pub temperature_supplied: bool,
52    /// True when the stored pressure was a supplied reading (0.49.0+). Absent/false = unknown:
53    /// files written before 0.49.0 cannot tell a typed 29.92 inHg from the default, so they keep
54    /// the legacy rule (29.92 inHg / 1013.25 hPa at a real altitude flies ICAO standard pressure).
55    #[serde(default, skip_serializing_if = "std::ops::Not::not")]
56    pub pressure_supplied: bool,
57    /// Relative humidity, PERCENT, 0 to 100 (50 = 50 %), whatever `units` says. Absent means
58    /// [`crate::atmosphere::DEFAULT_HUMIDITY_PERCENT`]. A stored sensor reading within
59    /// [`crate::HUMIDITY_SENSOR_TOLERANCE_PERCENT`] of 0 to 100 is kept as stored and flies as
60    /// the end it reads as; a value beyond that is refused on load
61    /// ([`Self::validate_humidity`]), never clamped.
62    #[serde(default = "default_humidity")]
63    pub humidity: f64,
64    #[serde(default)]
65    pub altitude: f64,
66    #[serde(default)]
67    pub bullet_name: Option<String>,
68    #[serde(default)]
69    pub created: Option<String>,
70    #[serde(default, skip_serializing_if = "Option::is_none")]
71    pub wind_speed: Option<f64>,
72    #[serde(default, skip_serializing_if = "Option::is_none")]
73    pub wind_direction: Option<f64>,
74    #[serde(default, skip_serializing_if = "Option::is_none")]
75    pub shooting_angle: Option<f64>,
76    #[serde(default, skip_serializing_if = "Option::is_none")]
77    pub auto_zero: Option<f64>,
78    #[serde(default, skip_serializing_if = "Option::is_none")]
79    pub twist_right: Option<bool>,
80    #[serde(default, skip_serializing_if = "Option::is_none")]
81    pub use_bc_segments: Option<bool>,
82    #[serde(default, skip_serializing_if = "Option::is_none")]
83    pub bullet_length: Option<f64>,
84    /// Turret elevation click graduation for `--adjustment-unit clicks` (MBA-1355), e.g. "0.1mil" or
85    /// "0.25moa" — parsed by `parse_click_value` at both save-time (validation) and
86    /// resolve-time (`resolve_click_values`). Unit-invariant (an angular graduation, not a
87    /// linear measurement), so `converted_to` leaves it untouched — see the `bc_segments`/
88    /// `drag_curve` comment below for why.
89    #[serde(default, skip_serializing_if = "Option::is_none")]
90    pub elevation_click: Option<String>,
91    /// Turret windage click graduation for `--adjustment-unit clicks` (MBA-1355). Falls back to the
92    /// resolved elevation graduation when unset — see `resolve_click_values`.
93    #[serde(default, skip_serializing_if = "Option::is_none")]
94    pub windage_click: Option<String>,
95    /// Velocity-banded BC breakpoints (MBA-1323 Phase 2: multi-row `.a7p` G1/G7 import).
96    /// `velocity_mps` in each entry is ALWAYS meters/second regardless of this profile's
97    /// `units` field — see [`ProfileBcSegment`]. The scalar `bc` field above is retained as
98    /// the highest-velocity row for tools that only understand a single BC; this list is the
99    /// authoritative full schedule once present. `None` (the pre-Phase-2 shape) means "no
100    /// velocity-banded schedule was captured" and callers fall back to the scalar `bc`.
101    ///
102    /// FORWARD-COMPAT WARNING (one-way): `#[serde(default)]` means this field round-trips
103    /// safely through readers that predate Phase 2, but "safely" only means *deserialization*
104    /// doesn't error — a pre-Phase-2 (or otherwise un-updated, e.g. stale WASM/bindings) reader
105    /// silently drops this key and solves with only the scalar `bc` above. That is a materially
106    /// different, unwarned answer whenever the schedule's non-fastest bands matter (empirically
107    /// confirmed: ~639 m/s vs. ~411 m/s impact velocity for the same imported profile — see
108    /// CLI_USAGE.md's "Multi-BC and CUSTOM drag curves" section). There is no sentinel trick
109    /// available here the way there is for `drag_curve`/CUSTOM below (a real, plausible-looking
110    /// `bc` value is unavoidable for back-compat with single-BC tools), so this direction of
111    /// version skew degrades silently by design and must stay documented rather than "fixed".
112    #[serde(default, skip_serializing_if = "Option::is_none")]
113    pub bc_segments: Option<Vec<ProfileBcSegment>>,
114    /// Full Mach/Cd drag curve (MBA-1323 Phase 2: `.a7p` `bc_type == CUSTOM` import). When
115    /// present, the scalar `bc`/`drag_model` fields are not physically meaningful for the
116    /// solve (`drag_model` reads "CUSTOM"; see `map_a7p_to_profile`'s CUSTOM handling for why
117    /// `bc` is an inert `0.0` sentinel rather than a real coefficient).
118    ///
119    /// FORWARD-COMPAT NOTE: unlike `bc_segments` above, a reader that predates Phase 2 (or
120    /// otherwise doesn't consume this field) is safe by construction, not just by omission: it
121    /// still sees `bc == 0.0` and `drag_model == "CUSTOM"`, so `BallisticInputs::validate_for_solve`
122    /// rejects the solve loudly ("bc_value must be finite and greater than zero") instead of
123    /// silently running physics under a fabricated coefficient.
124    #[serde(default, skip_serializing_if = "Option::is_none")]
125    pub drag_curve: Option<Vec<ProfileDragPoint>>,
126    /// Mach-keyed drop-scale-factor table (MBA-1357), accumulated one point at a time by
127    /// the `dsf` verb. `None` for every profile with no DSF calibration yet — including
128    /// every profile saved before this field existed, which loads clean and solves
129    /// untrued (same `#[serde(default)]` forward-compat pattern as `bc_segments`/
130    /// `drag_curve` above: an old reader that predates this field silently drops it on
131    /// re-save, degrading to untrued drop with no error).
132    #[serde(default, skip_serializing_if = "Option::is_none")]
133    pub dsf_points: Option<Vec<DsfPoint>>,
134    /// Which standard atmosphere `bc`/`bc_segments` are referenced to (MBA-1365): `None`
135    /// (the omitted-field default, and every profile saved before this field existed) or
136    /// `"icao"` mean ICAO; `"army-standard-metro"` declares the older Army Standard Metro
137    /// reference some vendor-published BCs use instead. Parsed by
138    /// `parse_bc_reference_profile_field`, written by `bc_reference_profile_field` (which
139    /// never writes `"icao"` — it stays the omitted default so an untouched profile
140    /// round-trips with no new key). Unit-invariant, like `bc_segments`/`drag_curve` above,
141    /// so `converted_to` leaves it untouched.
142    #[serde(default, skip_serializing_if = "Option::is_none")]
143    pub bc_reference: Option<String>,
144    /// Whether `pressure` is absolute station pressure or a sea-level-corrected altimeter
145    /// setting (QNH), mirroring `bc_reference` (MBA-1397): `None` (the omitted-field default,
146    /// and every profile saved before this field existed) or `"absolute"` mean absolute;
147    /// `"qnh"` declares a QNH pressure that must be reduced to station pressure before use.
148    /// Parsed by `parse_pressure_reference_profile_field`, written by
149    /// `pressure_reference_profile_field` (which never writes `"absolute"` -- it stays the
150    /// omitted default so an untouched profile round-trips with no new key).
151    #[serde(default, skip_serializing_if = "Option::is_none")]
152    pub pressure_reference: Option<String>,
153    /// Density altitude (MBA-1366), feet imperial / meters metric per `units` (same convention
154    /// as `altitude`). `None` (the omitted-field default, and every profile saved before this
155    /// field existed) means no density-altitude override is stored; a saved value supersedes
156    /// `altitude`/`pressure` when the profile is loaded (see `trajectory`'s
157    /// `--density-altitude` for the full precedence rule). `converted_to` rescales it exactly
158    /// like `altitude` since it shares the same feet/meters convention.
159    #[serde(default, skip_serializing_if = "Option::is_none")]
160    pub density_altitude: Option<f64>,
161    /// Deliberate vertical POI offset AT the zero range (MBA-1359, Kestrel "zero height"):
162    /// positive = the rifle is deliberately zeroed to impact HIGH by this much at the zero
163    /// distance. ALWAYS meters regardless of this profile's `units` field (same unit-fixed
164    /// convention as [`ProfileBcSegment::velocity_mps`]), so `converted_to` leaves it
165    /// untouched. `None` (the omitted-field default, and every profile saved before this
166    /// field existed) means no offset; an old reader silently drops it on re-save (the
167    /// `bc_segments` forward-compat pattern).
168    #[serde(default, skip_serializing_if = "Option::is_none")]
169    pub zero_poi_up_m: Option<f64>,
170    /// Deliberate horizontal POI offset AT the zero range (MBA-1359, Kestrel "zero
171    /// offset"): positive = impacts RIGHT. ALWAYS meters, like `zero_poi_up_m` above.
172    #[serde(default, skip_serializing_if = "Option::is_none")]
173    pub zero_poi_right_m: Option<f64>,
174    /// Lateral sight-to-bore mount offset (MBA-1396, offset-mounted optics): positive =
175    /// sight RIGHT of bore. ALWAYS meters (unit-fixed like the zero POI fields above), so
176    /// `converted_to` leaves it untouched; same `#[serde(default)]` forward-compat
177    /// pattern (an old reader silently drops it on re-save).
178    #[serde(default, skip_serializing_if = "Option::is_none")]
179    pub sight_offset_lateral_m: Option<f64>,
180    /// Elevation-axis scope tracking correction factor from a tall-target test
181    /// (MBA-1358, Litz), stored as the published ratio `actual measured travel /
182    /// dialed travel` (0.95 = the scope under-tracks by 5%). Elevation dial-unit
183    /// outputs (mil/MOA/SMOA/IPHY/clicks) are DIVIDED by this factor — an
184    /// under-tracking scope needs more dial — and dialed truing observations are
185    /// MULTIPLIED by it (scope-dial -> true angular); raw drop inches never scale.
186    /// NOTE on conventions: Kestrel's "Scope Cal" MULTIPLIES its factor into the
187    /// solution because it stores the reciprocal (dialed/actual); we divide because we
188    /// store the published actual/dialed — same physics, opposite bookkeeping.
189    /// Dimensionless, so `converted_to` leaves it untouched. Validated on load: must
190    /// be strictly between 0.5 and 1.5 (a factor outside that band means the
191    /// tall-target test went wrong, not that the scope does). `None` = 1.0 = no
192    /// correction. Derive with `ballistics tall-target`; overridden by
193    /// `--elevation-cf`.
194    #[serde(default, skip_serializing_if = "Option::is_none")]
195    pub elevation_cf: Option<f64>,
196    /// Windage-axis scope tracking correction factor (MBA-1358), same contract and
197    /// direction as `elevation_cf`: windage-axis dial-unit outputs (including mover
198    /// lead/ring) are divided by it; overridden by `--windage-cf`.
199    #[serde(default, skip_serializing_if = "Option::is_none")]
200    pub windage_cf: Option<f64>,
201    /// Named zero sets (MBA-1360): alternate zero distances and per-load dial
202    /// corrections (Lapua Sight-In POI / ATrag zero zones / Strelok multi-zero class).
203    /// Managed by `profile zero-set add|remove|list`; selected at solve time with
204    /// `--zero-set NAME`. Nothing here applies unless a set is explicitly selected —
205    /// the profile's own `zero_distance`/`auto_zero` remain the master zero.
206    ///
207    /// FORWARD-COMPAT (the `bc_segments` pattern, deliberately): `#[serde(default)]`
208    /// means a reader that predates this field loads the profile cleanly and solves
209    /// with the master zero — which is exactly what a CURRENT reader does when no
210    /// `--zero-set` is selected, so an old reader can never silently produce a
211    /// different default answer. Requesting an alternate set on an old binary fails
212    /// loudly at the flag (`--zero-set` is an unknown argument there). The one-way
213    /// skew is re-SAVING: an old reader that rewrites the profile silently drops this
214    /// key (documented, like `bc_segments`; there is no sentinel trick available that
215    /// wouldn't corrupt the master-zero fields old readers rely on).
216    #[serde(default, skip_serializing_if = "Option::is_none")]
217    pub zero_sets: Option<Vec<ProfileZeroSet>>,
218    /// The optic's reticle (MBA-1361), so `reticle hold --profile NAME` can place a
219    /// firing solution without being handed a description every time. Set with
220    /// `profile save --reticle-json <file>`; carried forward untouched by a re-save.
221    ///
222    /// Angular data only (milliradians from the optical center), so
223    /// `ProfileData::converted_to` (in `main.rs`) leaves it alone for the same reason it leaves
224    /// `elevation_click` alone — a subtension is not a linear measurement.
225    ///
226    /// FORWARD-COMPAT (the `bc_segments` pattern): `#[serde(default)]` means a reader that
227    /// predates this field loads the profile cleanly. Nothing about a trajectory depends
228    /// on it — it is a display/hold aid consumed only by the `reticle` command — so an old
229    /// reader cannot produce a different ballistic answer because of it; it simply has no
230    /// `reticle` verb. The one-way skew is re-SAVING, which drops the key, exactly as
231    /// documented for `bc_segments` and `zero_sets`.
232    #[serde(default, skip_serializing_if = "Option::is_none")]
233    pub reticle: Option<ReticleDescription>,
234    /// Turret mechanics and reticle hold bounds (MBA-1348): twelve fields (this one
235    /// through `hold_bound_right_mil` below) assembled by `ProfileData::optic_profile`
236    /// into a `ballistics_engine::optic::OpticProfile` for the dial/hold/hybrid
237    /// correction planner. Every one is independently `Option` and, like
238    /// `elevation_click`/`windage_click` above, ALWAYS stored in mil (or its own natural
239    /// type for `clicks_per_revolution`/`zero_stop`) regardless of this profile's `units`
240    /// field — angular turret/reticle geometry, not a linear measurement — so
241    /// `converted_to` leaves all twelve untouched. Set with `profile save
242    /// --clicks-per-rev/--zero-stop/--travel-up/--travel-down/--windage-travel-left/
243    /// --windage-travel-right/--turret-elev/--turret-wind/--hold-up/--hold-down/
244    /// --hold-left/--hold-right`; validated at save time via `optic_profile()` +
245    /// `OpticProfile::validate()` (a profile can never be saved with, say, a dialed
246    /// turret state outside its own declared travel, or a non-positive click size).
247    ///
248    /// FORWARD-COMPAT (the `bc_segments` pattern, deliberately): `#[serde(default)]`
249    /// means a reader that predates these fields loads the profile cleanly with every one
250    /// of them absent — identical to what a CURRENT reader does for a profile that never
251    /// set them, so an old reader can never silently produce a different ballistic
252    /// answer because of them (nothing about a trajectory solve reads them; only a later
253    /// dial/hold planner does). The one-way skew is re-SAVING on an old binary, which
254    /// silently drops all twelve keys, exactly as documented for `bc_segments`/
255    /// `zero_sets`/`reticle` above.
256    ///
257    /// This field specifically: click detents per full turret revolution, for turrets
258    /// whose cap marks revolutions at all (many hunting turrets do not). `None` means
259    /// unknown/not applicable, never a specific count.
260    #[serde(default, skip_serializing_if = "Option::is_none")]
261    pub clicks_per_revolution: Option<u32>,
262    /// Whether the elevation turret hard-stops at its lowest travel so it cannot be
263    /// dialed below zero (MBA-1348) — purely descriptive metadata, never read by
264    /// `plan_corrections` (see `OpticProfile::zero_stop`'s own doc comment for why).
265    /// `None` (the omitted-field default) means not recorded; `optic_profile()` treats
266    /// that the same as `Some(false)`.
267    #[serde(default, skip_serializing_if = "Option::is_none")]
268    pub zero_stop: Option<bool>,
269    /// Elevation travel remaining UP from the current zero (not the turret's mechanical
270    /// bottom), DIAL-space mil (MBA-1348). Required together with
271    /// `elevation_travel_down_mil` — `optic_profile()` returns a named-field `Err` if
272    /// only one of the pair is set, rather than silently treating the unset half as zero
273    /// travel (a specific, likely-false physical claim, not an honest "unknown").
274    #[serde(default, skip_serializing_if = "Option::is_none")]
275    pub elevation_travel_up_mil: Option<f64>,
276    /// Elevation travel remaining DOWN from the current zero, DIAL-space mil (MBA-1348).
277    /// See `elevation_travel_up_mil`.
278    #[serde(default, skip_serializing_if = "Option::is_none")]
279    pub elevation_travel_down_mil: Option<f64>,
280    /// Windage travel remaining LEFT from the current zero, DIAL-space mil (MBA-1348) —
281    /// `TravelLimits::down_mil` on the windage axis (see that type's doc comment for the
282    /// left/down convention). Required together with `windage_travel_right_mil`, like
283    /// `elevation_travel_up_mil`/`_down_mil` above.
284    #[serde(default, skip_serializing_if = "Option::is_none")]
285    pub windage_travel_left_mil: Option<f64>,
286    /// Windage travel remaining RIGHT from the current zero, DIAL-space mil (MBA-1348) —
287    /// `TravelLimits::up_mil` on the windage axis. See `windage_travel_left_mil`.
288    #[serde(default, skip_serializing_if = "Option::is_none")]
289    pub windage_travel_right_mil: Option<f64>,
290    /// The elevation turret's current dialed offset from zero, DIAL-space mil, signed:
291    /// positive is dialed UP (MBA-1348). Required together with
292    /// `turret_windage_dialed_mil` — `optic_profile()` returns a named-field `Err` if
293    /// only one axis of the pair is set, rather than silently assuming the other reads
294    /// zero.
295    #[serde(default, skip_serializing_if = "Option::is_none")]
296    pub turret_elevation_dialed_mil: Option<f64>,
297    /// The windage turret's current dialed offset from zero, DIAL-space mil, signed:
298    /// positive is dialed RIGHT (MBA-1348). See `turret_elevation_dialed_mil`.
299    #[serde(default, skip_serializing_if = "Option::is_none")]
300    pub turret_windage_dialed_mil: Option<f64>,
301    /// The reticle's usable hold extent ABOVE center, TRUE angular mil (MBA-1348) — see
302    /// `HoldBounds`, an explicit spec input (manufacturer spec sheet or bench
303    /// measurement), never derived from this profile's own `reticle` field. Required
304    /// together with `hold_bound_down_mil`/`hold_bound_left_mil`/`hold_bound_right_mil`
305    /// — all four or none.
306    #[serde(default, skip_serializing_if = "Option::is_none")]
307    pub hold_bound_up_mil: Option<f64>,
308    /// The reticle's usable hold extent BELOW center, TRUE angular mil (MBA-1348). See
309    /// `hold_bound_up_mil`.
310    #[serde(default, skip_serializing_if = "Option::is_none")]
311    pub hold_bound_down_mil: Option<f64>,
312    /// The reticle's usable hold extent LEFT of center, TRUE angular mil (MBA-1348). See
313    /// `hold_bound_up_mil`.
314    #[serde(default, skip_serializing_if = "Option::is_none")]
315    pub hold_bound_left_mil: Option<f64>,
316    /// The reticle's usable hold extent RIGHT of center, TRUE angular mil (MBA-1348). See
317    /// `hold_bound_up_mil`.
318    #[serde(default, skip_serializing_if = "Option::is_none")]
319    pub hold_bound_right_mil: Option<f64>,
320}
321
322/// One named zero condition / per-load dial correction (MBA-1360).
323///
324/// `zero_distance` uses the SAME display-unit convention as [`ProfileData::zero_distance`]
325/// (yards imperial / meters metric per the profile's `units` field), and
326/// `ProfileData::converted_to` (in `main.rs`) rescales it identically. `poi_up_mil`/`poi_right_mil`
327/// are constant ANGULAR dial corrections in MILs (unit-invariant, untouched by
328/// `converted_to`), ADDED to the dial outputs (elevation/windage adjustments) when the
329/// set is selected — positive = dial UP/RIGHT more; a load that impacts high/right
330/// relative to the master zero therefore stores negative values. This is deliberately
331/// dial-side (a constant angular correction per the ticket), unlike the MBA-1359
332/// linear-at-zero-range POI offsets, which bias the solved zero itself; the two compose.
333#[derive(Debug, Clone, Serialize, Deserialize, PartialEq)]
334pub struct ProfileZeroSet {
335    pub name: String,
336    #[serde(default, skip_serializing_if = "Option::is_none")]
337    pub zero_distance: Option<f64>,
338    #[serde(default, skip_serializing_if = "Option::is_none")]
339    pub poi_up_mil: Option<f64>,
340    #[serde(default, skip_serializing_if = "Option::is_none")]
341    pub poi_right_mil: Option<f64>,
342    #[serde(default, skip_serializing_if = "Option::is_none")]
343    pub notes: Option<String>,
344}
345
346/// One velocity-banded BC breakpoint (profile schema v2, MBA-1323 Phase 2). Stored as a raw
347/// breakpoint, NOT a pre-computed `velocity_min`/`velocity_max` band — banding into the
348/// engine's [`crate::BCSegmentData`] shape happens at solve time (`bc_segments_from_profile`), so the
349/// stored JSON stays a simple, order-independent list that round-trips cleanly.
350///
351/// `velocity_mps` is ALWAYS meters/second, independent of [`ProfileData::units`]. This is
352/// intentional (matches the engine's internal BC-segment plumbing, which is also always in
353/// engine units) and is why `ProfileData::converted_to` (in `main.rs`) leaves this field untouched — see
354/// the comment there.
355#[derive(Debug, Clone, Serialize, Deserialize, PartialEq)]
356pub struct ProfileBcSegment {
357    pub bc: f64,
358    pub velocity_mps: f64,
359}
360
361/// One Mach/Cd point of a saved custom drag curve (profile schema v2, MBA-1323 Phase 2).
362/// Both fields are unit-invariant (Mach is dimensionless; Cd is dimensionless), so
363/// `ProfileData::converted_to` (in `main.rs`) leaves `drag_curve` untouched too.
364#[derive(Debug, Clone, Serialize, Deserialize, PartialEq)]
365pub struct ProfileDragPoint {
366    pub mach: f64,
367    pub cd: f64,
368}
369
370fn default_unit_system() -> String {
371    "imperial".to_string()
372}
373fn default_temperature() -> f64 {
374    59.0
375}
376fn default_pressure() -> f64 {
377    29.92
378}
379fn default_humidity() -> f64 {
380    crate::atmosphere::DEFAULT_HUMIDITY_PERCENT
381}
382
383/// Assembles an all-or-nothing pair of angular profile fields — `OpticProfile`'s
384/// `TravelLimits`/`TurretState` axes — from two independently-`Option` values (MBA-1348).
385/// `None` only when NEITHER is set; `Some` only when BOTH are; a named-field `Err` when
386/// exactly one is. A silently-defaulted `0.0` for the missing half would assert a
387/// specific, likely-false physical fact (e.g. "zero down travel from zero") rather than
388/// "not recorded" — exactly the silent fabrication `OpticProfile`'s own doc comments
389/// warn against — so an incomplete pair is rejected by name instead of guessed at.
390///
391/// `a_flag`/`b_flag` name the CLI FLAGS (e.g. `"--travel-up"`), not the internal
392/// `ProfileData` struct fields (MBA-1348 review fix I2): the field↔flag mapping is not
393/// mechanical (`--travel-up` drops the axis prefix `elevation_travel_up_mil` carries;
394/// `--turret-elev` abbreviates `turret_elevation_dialed_mil`), and a user who typed
395/// `--travel-up` has no reason to recognize `elevation_travel_up_mil` in an error. This
396/// matches the convention two call sites above already use
397/// (`"--elevation-click '{v}' is invalid"`).
398pub fn require_angular_pair(
399    a_flag: &'static str,
400    a: Option<f64>,
401    b_flag: &'static str,
402    b: Option<f64>,
403) -> Result<Option<(f64, f64)>, String> {
404    match (a, b) {
405        (None, None) => Ok(None),
406        (Some(a), Some(b)) => Ok(Some((a, b))),
407        (Some(_), None) => Err(format!(
408            "{a_flag} is set but {b_flag} is not — both are required together (or neither)"
409        )),
410        (None, Some(_)) => Err(format!(
411            "{b_flag} is set but {a_flag} is not — both are required together (or neither)"
412        )),
413    }
414}
415
416/// The `require_angular_pair` all-or-nothing rule extended to `HoldBounds`' four fields
417/// (MBA-1348): all four or none, any other combination is a named-field `Err` (same
418/// no-silent-fabrication rationale — see `require_angular_pair`). Names the four CLI
419/// FLAGS in any error, not the internal struct fields (MBA-1348 review fix I2) — see
420/// `require_angular_pair`'s own doc comment for why that distinction matters.
421pub fn require_hold_bounds(
422    up: Option<f64>,
423    down: Option<f64>,
424    left: Option<f64>,
425    right: Option<f64>,
426) -> Result<Option<HoldBounds>, String> {
427    let flags = [
428        ("--hold-up", up),
429        ("--hold-down", down),
430        ("--hold-left", left),
431        ("--hold-right", right),
432    ];
433    let set_count = flags.iter().filter(|(_, v)| v.is_some()).count();
434    if set_count == 0 {
435        return Ok(None);
436    }
437    if set_count < 4 {
438        let missing: Vec<&str> = flags
439            .iter()
440            .filter(|(_, v)| v.is_none())
441            .map(|(name, _)| *name)
442            .collect();
443        return Err(format!(
444            "reticle hold bounds are incomplete — missing {} (all four of --hold-up/\
445             --hold-down/--hold-left/--hold-right are required together, or none)",
446            missing.join(", ")
447        ));
448    }
449    Ok(Some(HoldBounds {
450        up_mil: up.unwrap(),
451        down_mil: down.unwrap(),
452        left_mil: left.unwrap(),
453        right_mil: right.unwrap(),
454    }))
455}
456
457/// MBA-1358: a scope tracking correction factor must be strictly between 0.5 and 1.5.
458/// Values outside that band mean the tall-target test (or a hand edit) went wrong — a
459/// real scope does not mistrack by 50% — so they are a hard error naming the offending
460/// field/flag rather than a silently applied scale. The band itself lives in the shared
461/// `crate::adjustment::tracking_cf_in_range` so the WASM terminal enforces
462/// the identical bound.
463pub fn validate_tracking_cf(value: f64, source: &str) -> Result<(), String> {
464    if crate::adjustment::tracking_cf_in_range(value) {
465        Ok(())
466    } else {
467        Err(format!(
468            "{source} must be a tracking correction factor strictly between 0.5 and 1.5 \
469             (got {value}); derive it from a tall-target test with `ballistics tall-target`"
470        ))
471    }
472}
473
474impl ProfileData {
475    /// Assembles this profile's `OpticProfile` (MBA-1348) from `elevation_click`/
476    /// `windage_click` (parsed via `parse_click_value`, windage falling back to the
477    /// resolved elevation graduation — the same precedence `resolve_click_values` uses)
478    /// plus the twelve turret/hold fields declared alongside `reticle` above.
479    ///
480    /// Returns `Ok(None)` only when NONE of the twelve fields are set: the profile has
481    /// never been given any turret model at all. Every other combination either succeeds
482    /// (`Ok(Some(..))`) or is a named-field `Err` — including `elevation_click` itself
483    /// being unset while ANY of the other eleven fields IS set, since those eleven are
484    /// meaningless without a click graduation (`OpticProfile` cannot be constructed
485    /// without one, structurally) and silently ignoring them would let a save persist
486    /// turret/hold data no downstream code could ever use.
487    ///
488    /// Does NOT call `OpticProfile::validate()` itself — callers that need a
489    /// pre-validated profile (`profile save`) call it explicitly, so a validation
490    /// failure is attributed to the operation asking for it rather than to assembly.
491    pub fn optic_profile(&self) -> Result<Option<OpticProfile>, String> {
492        // Shape/pairing checks run FIRST and UNCONDITIONALLY -- before the elevation_click
493        // gate below -- so an incomplete travel/turret-state/hold-bound pair is rejected by
494        // name even on a profile that never set elevation_click at all (MBA-1348 review
495        // fix: a save with, e.g., only --travel-up and no --elevation-click previously
496        // skipped every one of these checks via the early `Ok(None)` return, silently
497        // persisting an incomplete pair no downstream code could ever have used anyway).
498        let elevation_travel = require_angular_pair(
499            "--travel-up",
500            self.elevation_travel_up_mil,
501            "--travel-down",
502            self.elevation_travel_down_mil,
503        )?
504        .map(|(up, down)| TravelLimits {
505            up_mil: up,
506            down_mil: down,
507        });
508
509        let windage_travel = require_angular_pair(
510            "--windage-travel-left",
511            self.windage_travel_left_mil,
512            "--windage-travel-right",
513            self.windage_travel_right_mil,
514        )?
515        .map(|(left, right)| TravelLimits {
516            down_mil: left,
517            up_mil: right,
518        });
519
520        let turret_state = require_angular_pair(
521            "--turret-elev",
522            self.turret_elevation_dialed_mil,
523            "--turret-wind",
524            self.turret_windage_dialed_mil,
525        )?
526        .map(|(elevation_mil, windage_mil)| TurretState {
527            elevation_mil,
528            windage_mil,
529        });
530
531        let reticle_hold_bounds = require_hold_bounds(
532            self.hold_bound_up_mil,
533            self.hold_bound_down_mil,
534            self.hold_bound_left_mil,
535            self.hold_bound_right_mil,
536        )?;
537
538        let Some(elev_str) = &self.elevation_click else {
539            // MBA-1348 review fix: every one of the other eleven fields is meaningless
540            // without a click graduation -- `OpticProfile` cannot even be constructed
541            // without one, structurally -- so silently accepting them here (the way a
542            // bare `Ok(None)` would) lets a save persist turret/hold data that no
543            // downstream code, including this profile's own future re-saves, could ever
544            // use. A profile that has genuinely never touched any of the twelve fields
545            // still returns Ok(None), unchanged.
546            if self.clicks_per_revolution.is_some()
547                || self.zero_stop.is_some()
548                || elevation_travel.is_some()
549                || windage_travel.is_some()
550                || turret_state.is_some()
551                || reticle_hold_bounds.is_some()
552            {
553                return Err(
554                    "turret/hold fields are set but --elevation-click is not -- a turret \
555                     model needs a click graduation to be usable at all; supply \
556                     --elevation-click, or also pass --clear-turret to clear the other \
557                     fields (e.g. after --clear-click removed the click alone)"
558                        .to_string(),
559                );
560            }
561            return Ok(None);
562        };
563        let elevation_click = parse_click_value(elev_str)?;
564        let windage_click = match &self.windage_click {
565            Some(s) => parse_click_value(s)?,
566            None => elevation_click,
567        };
568
569        Ok(Some(OpticProfile {
570            elevation_click,
571            windage_click,
572            clicks_per_revolution: self.clicks_per_revolution,
573            zero_stop: self.zero_stop.unwrap_or(false),
574            elevation_travel,
575            windage_travel,
576            turret_state,
577            reticle_hold_bounds,
578        }))
579    }
580
581    /// Parse this profile's `units` field into the CLI unit system it names.
582    ///
583    /// Factored out of the CLI's `converted_to` (which now calls this) so the bridge's
584    /// `profile.validate` applies the identical check with the identical message.
585    pub fn unit_system(&self) -> Result<UnitSystem, String> {
586        match self.units.trim().to_ascii_lowercase().as_str() {
587            "imperial" => Ok(UnitSystem::Imperial),
588            "metric" => Ok(UnitSystem::Metric),
589            other => Err(format!(
590                "Profile '{}' has unsupported units '{}'; expected 'imperial' or 'metric'",
591                self.name, other
592            )),
593        }
594    }
595
596    /// The stored `humidity`, checked by the engine's one validator,
597    /// [`crate::atmosphere::RelativeHumidity::try_percent`]. The CLI refuses to load a profile that
598    /// fails it, and the bridge's `profile.validate` reports it; the message names the profile and
599    /// the field, and says how to fix it.
600    ///
601    /// The fix it gives is an edit of the stored value, never a re-save: `profile save` is a
602    /// full overwrite of every field its flags can express (and it resets `bc_segments` and
603    /// `drag_curve`), so a re-save is not a safe way to repair one stored number.
604    pub fn validate_humidity(&self) -> Result<(), String> {
605        self.flown_humidity().map(|_| ())
606    }
607
608    /// The humidity, PERCENT, a flight of this profile flies: the stored `humidity` through
609    /// [`Self::validate_humidity`]'s one validator, so a stored sensor reading inside the band
610    /// is the end it reads as (102 flies as 100, -5 and -0 as 0) and anything farther out is
611    /// the same refusal.
612    ///
613    /// The one echo rule: a surface that reports the air FLOWN states this
614    /// value (the CLI's flight loader writes it into the profile it flies), and a surface that
615    /// displays the STORED document shows `humidity` as stored, saying what it flies as when
616    /// that is outside 0-100 ([`Self::flown_humidity_note`]).
617    pub fn flown_humidity(&self) -> Result<f64, String> {
618        crate::atmosphere::RelativeHumidity::try_percent(self.humidity)
619            .map(crate::atmosphere::RelativeHumidity::percent)
620            .map_err(|error| {
621                format!(
622                    "{}; edit the humidity stored in the profile",
623                    error.at_field(format!("profile '{}' field humidity", self.name))
624                )
625            })
626    }
627
628    /// What a STORED humidity outside 0-100 flies as, for a surface that shows the stored value:
629    /// `Some(100.0)` for a stored 102, `Some(0.0)` for a stored -5; `None` for a stored value in
630    /// 0-100 (it flies as itself) and for one that does not fly at all (beyond the band, or not
631    /// finite), which [`Self::validate_humidity`] reports instead.
632    pub fn flown_humidity_note(&self) -> Option<f64> {
633        // The one validator decides: it moves a stored value only when that value is a band
634        // reading outside 0-100 (-0 snaps to 0, which compares equal, so it needs no note).
635        let flown = self.flown_humidity().ok()?;
636        (flown != self.humidity).then_some(flown)
637    }
638
639    /// The station air a flight of this profile's OWN stored atmosphere flies, the way every
640    /// CLI command that takes a saved profile reads it when no station flag is typed (`dsf
641    /// --saved-profile` always): the stored readings in the profile's `units`, converted to
642    /// metric; a stored density altitude flies its derived station triple with both readings
643    /// supplied; a stored `pressure_reference` of `qnh` is reduced to station pressure at the
644    /// profile's altitude; otherwise each reading's presence is the profile's marker (a profile
645    /// written before 0.49.0 has none and keeps the legacy rule). An unmarked stored default
646    /// (29.92 inHg, 1013.25 hPa) is taken as stored here; the CLI flies the run's own default in
647    /// its place, which differs from it by at most the 0.04 hPa between the two.
648    ///
649    /// Returns the conditions (°C, hPa, the stored humidity percent, m), the presence a solver
650    /// resolves them with, and where the station's readings came from (the stored reading, a
651    /// stored QNH reduced here, kept as it is stored so a refusal quotes it, the standard
652    /// pressure at the altitude for an omitted one, or a stored density altitude's station, and
653    /// its temperature unless one is stored as a reading); an error for `units` or a
654    /// `pressure_reference` the profile cannot be read in.
655    pub fn stored_station(
656        &self,
657    ) -> Result<
658        (
659            crate::cli_api::AtmosphericConditions,
660            crate::atmosphere::StationAtmospherePresence,
661            crate::atmosphere::StationOrigin,
662        ),
663        String,
664    > {
665        use crate::atmosphere::{
666            reduce_qnh_to_station_pressure, resolve_atmosphere_for_density_altitude,
667            PressureReferenceMode, StationAtmospherePresence, StationOrigin,
668        };
669        let units = self.unit_system()?;
670        // The CLI's own `UnitConverter` factors and default pressures, in the same order.
671        let to_celsius = |value: f64| match units {
672            UnitSystem::Metric => value,
673            UnitSystem::Imperial => (value - 32.0) * 5.0 / 9.0,
674        };
675        let to_hpa = |value: f64, system: UnitSystem| match system {
676            UnitSystem::Metric => value,
677            UnitSystem::Imperial => value * 33.8639,
678        };
679        let to_meters = |value: f64| match units {
680            UnitSystem::Metric => value,
681            UnitSystem::Imperial => value * 0.3048,
682        };
683        let (temperature_c, pressure_hpa, altitude_m, presence, origin) = match self
684            .density_altitude
685        {
686            Some(density_altitude) => {
687                let explicit_temperature_c = self
688                    .temperature_supplied
689                    .then(|| to_celsius(self.temperature));
690                let (altitude_m, temperature_c, pressure_hpa) =
691                    resolve_atmosphere_for_density_altitude(
692                        to_meters(density_altitude),
693                        explicit_temperature_c,
694                    );
695                (
696                    temperature_c,
697                    pressure_hpa,
698                    altitude_m,
699                    StationAtmospherePresence::BOTH,
700                    StationOrigin::density_altitude(explicit_temperature_c.is_some()),
701                )
702            }
703            None => {
704                let altitude_m = to_meters(self.altitude);
705                let entered_hpa = to_hpa(self.pressure, units);
706                let mode = match self.pressure_reference.as_deref().map(str::trim) {
707                    None | Some("") => PressureReferenceMode::Absolute,
708                    Some(text) => match text.to_ascii_lowercase().as_str() {
709                        "absolute" => PressureReferenceMode::Absolute,
710                        "qnh" => PressureReferenceMode::Qnh,
711                        other => {
712                            return Err(format!(
713                                "invalid pressure_reference '{other}' (expected 'absolute' or \
714                                 'qnh')"
715                            ))
716                        }
717                    },
718                };
719                let (pressure_hpa, pressure_supplied) = match mode {
720                    PressureReferenceMode::Absolute => (entered_hpa, self.pressure_supplied),
721                    PressureReferenceMode::Qnh => {
722                        // A stored QNH is a reading unless it is the omitted default of either
723                        // unit system (the CLI's `saved_pressure_is_reading`).
724                        let reading = self.pressure_supplied
725                            || [(UnitSystem::Metric, 1013.25), (UnitSystem::Imperial, 29.92)]
726                                .into_iter()
727                                .all(|(system, omitted)| {
728                                    (entered_hpa - to_hpa(omitted, system)).abs() >= 1e-6
729                                });
730                        (
731                            reduce_qnh_to_station_pressure(entered_hpa, altitude_m),
732                            reading,
733                        )
734                    }
735                };
736                let presence =
737                    StationAtmospherePresence::new(self.temperature_supplied, pressure_supplied);
738                (
739                    to_celsius(self.temperature),
740                    pressure_hpa,
741                    altitude_m,
742                    presence,
743                    // From the pressure as stored (a QNH before its reduction).
744                    StationOrigin::resolving(entered_hpa, altitude_m, mode, presence),
745                )
746            }
747        };
748        Ok((
749            crate::cli_api::AtmosphericConditions {
750                temperature: temperature_c,
751                pressure: pressure_hpa,
752                humidity: self.humidity,
753                altitude: altitude_m,
754            },
755            presence,
756            origin,
757        ))
758    }
759
760    /// This profile's stored air refused by the rule a flight of it applies (a humidity outside
761    /// the sensor band, a temperature at or below absolute zero, a pressure at or below 0, a
762    /// density altitude no air has, air that cannot exist), named in the words of whoever reads
763    /// the profile (`fields`: humidity, temperature, pressure, altitude), with the temperature,
764    /// pressure and every altitude in the profile's own units; `None` when the air flies, or
765    /// when [`Self::stored_station`] cannot read the profile at all (its own refusal is reported
766    /// where that is checked).
767    ///
768    /// A profile with a stored density altitude flies its station
769    /// ([`crate::atmosphere::station_for_density_altitude`]), so a caller names the altitude and
770    /// the pressure (and the temperature, unless one is stored as a reading) by the density
771    /// altitude's field, as [`Self::air_refusal`] does.
772    pub fn air_refusal_in(
773        &self,
774        fields: [crate::atmosphere::AirField<'_>; 4],
775    ) -> Option<crate::atmosphere::AirRefusal> {
776        use crate::atmosphere::AirUnits;
777        let air_units = match self.unit_system().ok()? {
778            UnitSystem::Metric => AirUnits::METRIC,
779            UnitSystem::Imperial => AirUnits::IMPERIAL,
780        };
781        if let Some(density_altitude) = self.density_altitude {
782            let (to_celsius, to_meters) = self.station_converters().ok()?;
783            let explicit_temperature_c = self
784                .temperature_supplied
785                .then(|| to_celsius(self.temperature));
786            if let Err(error) = crate::atmosphere::station_for_density_altitude(
787                to_meters(density_altitude),
788                explicit_temperature_c,
789            ) {
790                let [humidity, temperature, pressure, altitude] = fields;
791                let temperature_c = explicit_temperature_c.unwrap_or(f64::NAN);
792                return Some(
793                    error.refusal_in(
794                        &crate::atmosphere::AirSpelling {
795                            humidity,
796                            temperature,
797                            pressure,
798                            altitude,
799                            humidity_sent: self.humidity,
800                            temperature_text: air_units.temperature.text(temperature_c),
801                            temperature_unit: air_units.temperature,
802                            temperature_origin: crate::atmosphere::StationOrigin::density_altitude(
803                                explicit_temperature_c.is_some(),
804                            )
805                            .temperature,
806                            pressure_text: String::new(),
807                            pressure_origin:
808                                crate::atmosphere::StationPressureOrigin::DensityAltitude,
809                            qnh_text: None,
810                            altitude_unit: air_units.altitude,
811                        },
812                        to_meters(density_altitude),
813                        temperature_c,
814                        f64::NAN,
815                    ),
816                );
817            }
818        }
819        let (conditions, presence, origin) = self.stored_station().ok()?;
820        conditions.air_refusal_from(presence, origin, fields, self.humidity, air_units)
821    }
822
823    /// The profile's `units` conversions of a stored temperature to °C and an altitude to
824    /// metres, the CLI's own factors.
825    #[allow(clippy::type_complexity)]
826    fn station_converters(&self) -> Result<(fn(f64) -> f64, fn(f64) -> f64), String> {
827        Ok(match self.unit_system()? {
828            UnitSystem::Metric => (|value| value, |value| value),
829            UnitSystem::Imperial => (|value| (value - 32.0) * 5.0 / 9.0, |value| value * 0.3048),
830        })
831    }
832
833    /// [`Self::air_refusal_in`] in the stored profile's own words: `profile '<name>' field
834    /// humidity = 100 at 100 °C and 1013.25 hPa: no such air exists: ...`,
835    /// `profile '<name>' field pressure = -1 inHg: pressure must be greater than 0`, located at
836    /// the stored document's member (`$.humidity`, `$.temperature`, `$.pressure`,
837    /// `$.altitude`). A stored density altitude is the field of the altitude and the pressure
838    /// it gives the station, and of its temperature unless one is stored as a reading
839    /// (`profile '<name>' field density_altitude = 200000 ft: no air has this density altitude:
840    /// ...`, at `$.density_altitude`). The rule every flight of the profile applies, for the
841    /// surfaces that read a profile without flying it: `profile.validate`, `.a7p` export,
842    /// `profile show`.
843    pub fn air_refusal(&self) -> Option<crate::atmosphere::AirRefusal> {
844        let names = [
845            "humidity",
846            "temperature",
847            "pressure",
848            "altitude",
849            "density_altitude",
850        ]
851        .map(|field| format!("profile '{}' field {field}", self.name));
852        let field = |index: usize, path: &'static str| crate::atmosphere::AirField {
853            name: &names[index],
854            path,
855        };
856        let density_altitude = field(4, "$.density_altitude");
857        let derived = self.density_altitude.is_some();
858        self.air_refusal_in([
859            field(0, "$.humidity"),
860            if derived && !self.temperature_supplied {
861                density_altitude
862            } else {
863                field(1, "$.temperature")
864            },
865            if derived {
866                density_altitude
867            } else {
868                field(2, "$.pressure")
869            },
870            if derived {
871                density_altitude
872            } else {
873                field(3, "$.altitude")
874            },
875        ])
876    }
877
878    /// The cheap invariants the CLI already applies to a saved profile, collected instead
879    /// of short-circuited: the `units` string (`converted_to`'s gate), the stored humidity
880    /// ([`Self::validate_humidity`], `load_profile`'s gate) and, when it is one, whether the
881    /// stored air can exist at all ([`Self::air_refusal`], every flight's gate), the MBA-1358
882    /// tracking-CF band (`load_profile`'s gate), and the MBA-1348 turret/optic assembly +
883    /// validation (`profile save`'s gate, including `parse_click_value` on the stored
884    /// click graduations). No new physics checks — this is exactly the existing load/save
885    /// surface, aggregated for the bridge's `profile.validate`. Empty means the profile
886    /// passes every one of those gates.
887    pub fn validation_warnings(&self) -> Vec<String> {
888        let mut warnings = Vec::new();
889        if let Err(err) = self.unit_system() {
890            warnings.push(err);
891        }
892        if let Err(err) = self.validate_humidity() {
893            warnings.push(err);
894        } else if let Some(refusal) = self.air_refusal() {
895            // The rule every flight of this profile applies to its air, so a profile reported
896            // valid is one every solve of it can fly.
897            warnings.push(format!(
898                "{refusal}; edit the humidity, temperature, pressure, altitude or density \
899                 altitude stored in the profile"
900            ));
901        }
902        if let Some(cf) = self.elevation_cf {
903            if let Err(err) = validate_tracking_cf(cf, "profile field elevation_cf") {
904                warnings.push(err);
905            }
906        }
907        if let Some(cf) = self.windage_cf {
908            if let Err(err) = validate_tracking_cf(cf, "profile field windage_cf") {
909                warnings.push(err);
910            }
911        }
912        match self.optic_profile() {
913            Err(err) => warnings.push(format!("turret/optic model: {err}")),
914            Ok(Some(optic)) => {
915                if let Err(err) = optic.validate() {
916                    warnings.push(format!("turret/optic model: {err}"));
917                }
918            }
919            Ok(None) => {}
920        }
921        warnings
922    }
923}
924
925#[cfg(test)]
926mod tests {
927    use super::*;
928
929    /// A literal on-disk profile document exercising the big wire surface: the five
930    /// mandatory fields, bc_segments, drag_curve, dsf_points, tracking CFs, named zero
931    /// sets with POI corrections, the click graduations plus all twelve turret/hold
932    /// fields, and a reticle — PLUS a top-level key this build has never heard of
933    /// ("future_field") and an unknown key nested inside a zero set, because tolerating
934    /// unknown keys (no `deny_unknown_fields`) is the documented forward-compat behavior
935    /// this struct has always had and the move into the library must not change.
936    const FIXTURE: &str = r#"{
937        "name": "wire-shape-fixture",
938        "velocity": 762.0,
939        "bc": 0.243,
940        "mass": 11.33980925,
941        "diameter": 7.8232,
942        "drag_model": "G7",
943        "twist_rate": 254.0,
944        "sight_height": 50.8,
945        "zero_distance": 91.44,
946        "units": "metric",
947        "temperature": 15.0,
948        "pressure": 1013.207888,
949        "humidity": 55.0,
950        "altitude": 304.8,
951        "bullet_name": "175gr SMK",
952        "created": "1755400000",
953        "wind_speed": 4.4704,
954        "wind_direction": 90.0,
955        "shooting_angle": -5.0,
956        "auto_zero": 91.44,
957        "twist_right": false,
958        "use_bc_segments": true,
959        "bullet_length": 30.48,
960        "elevation_click": "0.1mil",
961        "windage_click": "0.25moa",
962        "bc_segments": [
963            {"bc": 0.243, "velocity_mps": 792.0},
964            {"bc": 0.230, "velocity_mps": 400.0}
965        ],
966        "drag_curve": [
967            {"mach": 0.5, "cd": 0.23},
968            {"mach": 1.2, "cd": 0.45},
969            {"mach": 3.0, "cd": 0.28}
970        ],
971        "dsf_points": [
972            {"mach": 0.9, "dsf": 1.04}
973        ],
974        "bc_reference": "army-standard-metro",
975        "pressure_reference": "qnh",
976        "density_altitude": 500.0,
977        "zero_poi_up_m": 0.05,
978        "zero_poi_right_m": -0.02,
979        "sight_offset_lateral_m": 0.01,
980        "elevation_cf": 0.97,
981        "windage_cf": 1.02,
982        "zero_sets": [
983            {"name": "suppressed", "zero_distance": 200.0, "poi_up_mil": -0.3,
984             "poi_right_mil": 0.1, "notes": "suppressed load",
985             "zero_set_future_field": true},
986            {"name": "match", "poi_up_mil": 0.25}
987        ],
988        "reticle": {
989            "name": "mil-grid 0.5/10",
990            "focal_plane": "ffp",
991            "reference_magnification": 10.0,
992            "marks": [
993                {"down_mil": 0.0, "right_mil": 0.0, "kind": "center"},
994                {"down_mil": 1.0, "right_mil": 0.0, "kind": "hash", "label": "1.0"}
995            ]
996        },
997        "clicks_per_revolution": 100,
998        "zero_stop": true,
999        "elevation_travel_up_mil": 26.0,
1000        "elevation_travel_down_mil": 4.0,
1001        "windage_travel_left_mil": 12.0,
1002        "windage_travel_right_mil": 12.0,
1003        "turret_elevation_dialed_mil": 5.4,
1004        "turret_windage_dialed_mil": -0.2,
1005        "hold_bound_up_mil": 5.0,
1006        "hold_bound_down_mil": 10.0,
1007        "hold_bound_left_mil": 6.0,
1008        "hold_bound_right_mil": 6.0,
1009        "future_field": {"nested": [1, 2, 3]}
1010    }"#;
1011
1012    /// deserialize -> serialize -> deserialize is the identity on every stored field,
1013    /// and the two serializations are byte-identical to each other (the engine's own
1014    /// output is stable). Unknown input keys are tolerated on the way in — the
1015    /// pre-existing behavior — and are NOT preserved on the way out (serde drops them;
1016    /// also pre-existing, documented in the module doc).
1017    #[test]
1018    fn wire_shape_round_trips_field_for_field() {
1019        let first: ProfileData = serde_json::from_str(FIXTURE).expect("fixture must load");
1020        let serialized = serde_json::to_string(&first).expect("serialize");
1021        let second: ProfileData = serde_json::from_str(&serialized).expect("reload");
1022
1023        // The engine re-serializes its own output identically.
1024        assert_eq!(
1025            serde_json::to_value(&first).unwrap(),
1026            serde_json::to_value(&second).unwrap()
1027        );
1028
1029        // Field-level equality across the whole surface (ProfileData does not derive
1030        // PartialEq, deliberately — nothing in production compares whole profiles).
1031        assert_eq!(second.name, "wire-shape-fixture");
1032        assert_eq!(second.velocity.to_bits(), 762.0f64.to_bits());
1033        assert_eq!(second.bc.to_bits(), 0.243f64.to_bits());
1034        assert_eq!(second.mass.to_bits(), 11.33980925f64.to_bits());
1035        assert_eq!(second.diameter.to_bits(), 7.8232f64.to_bits());
1036        assert_eq!(second.drag_model, "G7");
1037        assert_eq!(second.twist_rate, Some(254.0));
1038        assert_eq!(second.sight_height, Some(50.8));
1039        assert_eq!(second.zero_distance, Some(91.44));
1040        assert_eq!(second.units, "metric");
1041        assert_eq!(second.temperature.to_bits(), 15.0f64.to_bits());
1042        assert_eq!(second.pressure.to_bits(), 1013.207888f64.to_bits());
1043        assert_eq!(second.humidity.to_bits(), 55.0f64.to_bits());
1044        assert_eq!(second.altitude.to_bits(), 304.8f64.to_bits());
1045        assert_eq!(second.bullet_name.as_deref(), Some("175gr SMK"));
1046        assert_eq!(second.created.as_deref(), Some("1755400000"));
1047        assert_eq!(second.wind_speed, Some(4.4704));
1048        assert_eq!(second.wind_direction, Some(90.0));
1049        assert_eq!(second.shooting_angle, Some(-5.0));
1050        assert_eq!(second.auto_zero, Some(91.44));
1051        assert_eq!(second.twist_right, Some(false));
1052        assert_eq!(second.use_bc_segments, Some(true));
1053        assert_eq!(second.bullet_length, Some(30.48));
1054        assert_eq!(second.elevation_click.as_deref(), Some("0.1mil"));
1055        assert_eq!(second.windage_click.as_deref(), Some("0.25moa"));
1056        assert_eq!(
1057            second.bc_segments,
1058            Some(vec![
1059                ProfileBcSegment {
1060                    bc: 0.243,
1061                    velocity_mps: 792.0
1062                },
1063                ProfileBcSegment {
1064                    bc: 0.230,
1065                    velocity_mps: 400.0
1066                },
1067            ])
1068        );
1069        assert_eq!(
1070            second.drag_curve,
1071            Some(vec![
1072                ProfileDragPoint {
1073                    mach: 0.5,
1074                    cd: 0.23
1075                },
1076                ProfileDragPoint {
1077                    mach: 1.2,
1078                    cd: 0.45
1079                },
1080                ProfileDragPoint {
1081                    mach: 3.0,
1082                    cd: 0.28
1083                },
1084            ])
1085        );
1086        assert_eq!(
1087            second.dsf_points,
1088            Some(vec![DsfPoint {
1089                mach: 0.9,
1090                dsf: 1.04
1091            }])
1092        );
1093        assert_eq!(second.bc_reference.as_deref(), Some("army-standard-metro"));
1094        assert_eq!(second.pressure_reference.as_deref(), Some("qnh"));
1095        assert_eq!(second.density_altitude, Some(500.0));
1096        assert_eq!(second.zero_poi_up_m, Some(0.05));
1097        assert_eq!(second.zero_poi_right_m, Some(-0.02));
1098        assert_eq!(second.sight_offset_lateral_m, Some(0.01));
1099        assert_eq!(second.elevation_cf, Some(0.97));
1100        assert_eq!(second.windage_cf, Some(1.02));
1101        let sets = second.zero_sets.as_deref().expect("zero_sets kept");
1102        assert_eq!(sets.len(), 2);
1103        assert_eq!(sets[0].name, "suppressed");
1104        assert_eq!(sets[0].zero_distance, Some(200.0));
1105        assert_eq!(sets[0].poi_up_mil, Some(-0.3));
1106        assert_eq!(sets[0].poi_right_mil, Some(0.1));
1107        assert_eq!(sets[0].notes.as_deref(), Some("suppressed load"));
1108        assert_eq!(sets[1].name, "match");
1109        assert_eq!(sets[1].zero_distance, None);
1110        assert_eq!(sets[1].poi_up_mil, Some(0.25));
1111        assert_eq!(sets[1].poi_right_mil, None);
1112        let reticle = second.reticle.as_ref().expect("reticle kept");
1113        assert_eq!(reticle.name, "mil-grid 0.5/10");
1114        assert_eq!(reticle.marks.len(), 2);
1115        assert_eq!(reticle.marks[1].label.as_deref(), Some("1.0"));
1116        assert_eq!(second.clicks_per_revolution, Some(100));
1117        assert_eq!(second.zero_stop, Some(true));
1118        assert_eq!(second.elevation_travel_up_mil, Some(26.0));
1119        assert_eq!(second.elevation_travel_down_mil, Some(4.0));
1120        assert_eq!(second.windage_travel_left_mil, Some(12.0));
1121        assert_eq!(second.windage_travel_right_mil, Some(12.0));
1122        assert_eq!(second.turret_elevation_dialed_mil, Some(5.4));
1123        assert_eq!(second.turret_windage_dialed_mil, Some(-0.2));
1124        assert_eq!(second.hold_bound_up_mil, Some(5.0));
1125        assert_eq!(second.hold_bound_down_mil, Some(10.0));
1126        assert_eq!(second.hold_bound_left_mil, Some(6.0));
1127        assert_eq!(second.hold_bound_right_mil, Some(6.0));
1128
1129        // Unknown keys were tolerated (this test got this far) and dropped on re-save
1130        // (pre-existing serde behavior, documented in the module doc): no invented keys.
1131        let reserialized: serde_json::Value = serde_json::from_str(&serialized).unwrap();
1132        assert!(reserialized.get("future_field").is_none());
1133
1134        // This fixture also passes every load/save invariant `validation_warnings`
1135        // aggregates (units, CF band, optic assembly + validation).
1136        assert_eq!(second.validation_warnings(), Vec::<String>::new());
1137    }
1138
1139    /// The minimal legacy (pre-v2) document: only the five mandatory fields. The four
1140    /// defaulted scalars fill in (imperial / 59 F / 29.92 inHg / 50%), every `Option`
1141    /// stays `None`, and — load-bearing for on-disk compatibility — re-serialization
1142    /// keeps the non-`skip_serializing_if` optional keys (`twist_rate`, `sight_height`,
1143    /// `zero_distance`, `bullet_name`, `created`) present as JSON `null` while every
1144    /// `skip_serializing_if` key stays absent.
1145    #[test]
1146    fn legacy_minimal_document_defaults_and_reserializes_with_stable_keys() {
1147        let legacy = r#"{
1148            "name": "legacy",
1149            "velocity": 2500.0,
1150            "bc": 0.475,
1151            "mass": 175.0,
1152            "diameter": 0.308,
1153            "drag_model": "G1"
1154        }"#;
1155        let profile: ProfileData = serde_json::from_str(legacy).expect("legacy must load");
1156        assert_eq!(profile.units, "imperial");
1157        assert_eq!(profile.temperature.to_bits(), 59.0f64.to_bits());
1158        assert_eq!(profile.pressure.to_bits(), 29.92f64.to_bits());
1159        assert_eq!(profile.humidity.to_bits(), 50.0f64.to_bits());
1160        assert_eq!(profile.altitude.to_bits(), 0.0f64.to_bits());
1161        assert!(profile.bc_segments.is_none());
1162        assert!(profile.zero_sets.is_none());
1163
1164        let out: serde_json::Value =
1165            serde_json::from_str(&serde_json::to_string(&profile).unwrap()).unwrap();
1166        // Plain-`default` options serialize as explicit null (the historical shape)...
1167        assert!(out
1168            .get("twist_rate")
1169            .is_some_and(serde_json::Value::is_null));
1170        assert!(out
1171            .get("bullet_name")
1172            .is_some_and(serde_json::Value::is_null));
1173        assert!(out.get("created").is_some_and(serde_json::Value::is_null));
1174        // ...while `skip_serializing_if` options stay absent entirely.
1175        for absent in [
1176            "wind_speed",
1177            "bc_segments",
1178            "drag_curve",
1179            "dsf_points",
1180            "zero_sets",
1181            "reticle",
1182            "elevation_click",
1183            "elevation_cf",
1184            "clicks_per_revolution",
1185        ] {
1186            assert!(out.get(absent).is_none(), "{absent} must stay absent");
1187        }
1188        assert_eq!(profile.validation_warnings(), Vec::<String>::new());
1189    }
1190
1191    /// `validation_warnings` reports exactly the CLI's own gates: an out-of-band
1192    /// tracking CF (load gate), a bad units string (`converted_to` gate), and an
1193    /// incomplete turret pair / unparseable click (save gate) — and nothing for a
1194    /// profile that merely leaves everything optional unset.
1195    #[test]
1196    fn validation_warnings_mirror_the_cli_gates() {
1197        let mut profile: ProfileData = serde_json::from_str(FIXTURE).unwrap();
1198        profile.elevation_cf = Some(0.4); // outside the (0.5, 1.5) band
1199        profile.units = "nautical".to_string();
1200        profile.elevation_travel_down_mil = None; // breaks the all-or-nothing pair
1201        let warnings = profile.validation_warnings();
1202        assert_eq!(warnings.len(), 3, "{warnings:?}");
1203        assert!(
1204            warnings.iter().any(|w| w.contains("elevation_cf")),
1205            "{warnings:?}"
1206        );
1207        assert!(
1208            warnings.iter().any(|w| w.contains("unsupported units")),
1209            "{warnings:?}"
1210        );
1211        assert!(
1212            warnings.iter().any(|w| w.contains("--travel-down")),
1213            "{warnings:?}"
1214        );
1215    }
1216}