pub fn check_station_temperature_c(
temperature_c: f64,
) -> Result<(), AtmosphereError>Expand description
The one rule a station temperature, °C, is held to on its own, on every surface: finite and
above absolute zero (-273.15 °C). Nothing narrower: outside 173.15-373.15 K (-100 °C to
100 °C) the humidity terms are extrapolated, never refused. StationAir::new applies it,
and then the impossible-air rule, which is the only other reason a temperature is refused (in
flight too: AtmosphereErrorReason::AirAloftBelowAbsoluteZero). A surface that checks a
reading as it is typed (a CLI flag, converted to °C) applies this same function, so a reading
is accepted or refused alike everywhere.
use ballistics_engine::atmosphere::check_station_temperature_c;
assert!(check_station_temperature_c(250.0).is_ok()); // extrapolated, not refused
assert!(check_station_temperature_c(-150.0).is_ok());
assert!(check_station_temperature_c(-273.15).is_err()); // absolute zero
assert!(check_station_temperature_c(f64::NAN).is_err());§Errors
AtmosphereErrorReason::NotFinite or AtmosphereErrorReason::AtOrBelowAbsoluteZero,
on temperature_c.